We offer the most competitive prices for HVAC Heating Cooling Air Conditioning products and installation in Arlington – Alexandria – Northern Virginia – Washington DC and Maryland
Dedicated Outside Air Systems PremiSys® Fusion Mitsubishi

Call Perry Aire today 703-521-2226!

 
 
634637729045120948

mitsu-elec-hvac-stacked_c

Offering Mitsubishi PremiSys® Fusion Dedicated Outside Air Systems in:

VIRGINIA: Alexandria, Annandale, Arlington, Ashburn, Burke, Centreville, Chantilly, Crystal City, Dale City, Dulles, Fairfax, Falls Church, Fort Belvoir, Great Falls, Herndon, Leesburg, Lincoln, Lorton, Manassas, McLean, Oakton, Purcellville, Reston, Springfield, Stafford, Sterling, Vienna, Woodbridge.

MARYLAND: Annapolis, Aspen Hill, Beltsville, Bethesda, Chevy Chase, College Park, Gaithersburg, Hampstead, Hyattsville, Lanham, Laurel, Montgomery Village, Potomac, Rockville, Silver Spring, Takoma Park, Temple Hills, National Harbor, Cabin John, East Riverdale, Riverdale, Landover, Cheverly, Oxon Hill, Fort Washington, Indian head, Morningside.

WASHINGTON, DC

PremiSys® Fusion Dedicated Outside Air Systems

The PremiSys® series of rooftop ventilation products is a premier solution for conditioning outdoor air for commercial buildings. Designed to handle 100% outdoor air with energy recovery models, PremiSys products offer premium features ideal for handling ventilation air in variable refrigerant flow (VRF) applications.

The PremiSys Fusion is the latest addition to the family of dedicated outdoor air systems. The MPF-1 and MPF-2 models (split system with energy recovery) are pre-engineered to provide semi-custom flexibility while maintaining the quality, consistency, and value of a standardized product. Take advantage of the split-system design to further enhance the flexibility of applying Mitsubishi Electric products to any building.

  • Direct-drive plenum fans with factory-mounted variable frequency drives (VFD’s) handle up to 5,000 CFM and 3 in. wg external static pressure.
  • Pre-painted cabinet with 2-inch double-wall construction.
  • Downturn intake hood with aluminum mesh filters.
  • Microprocessor controls for stand-alone functionality or communication through Mitsubishi Electric’s M-Net.
  • Additional components required for communication via other protocols, such as BACnet®, LonWorks®, or Morbus®.
  • Multiple filter options including MERV 8 (standard, MERV 13 (optional), or a combination MERV 8/13).
  • Optional accessories include smoke detectors and condenser hail guards.